Test instruments for testing the combustion properties of plastics and non-metallic materials. It is suitable for laboratory determination of the combustion properties of plastic and non-metallic specimens in the horizontal or vertical direction under 50W flame conditions. 【Relevant Standards】
    Design standard: GB-T2408-2008 “Testing of Plastic Combustion Performance – Horizontal and Vertical Method” (ANSI/UL94-2006) GBT10707-2008 “Determination of Rubber Combustion Performance” Method B (i.e., GB-T13488 “Determination of Rubber Combustion Performance – Vertical Combustion Method”) ANSI/UL94 GJB360B-2009 Test Method for Electronic and Electrical Components GB/T5169.16-2008IEC60950-1
【Scope of application】:Test instruments for testing the combustion properties of plastics and non-metallic materials. It is suitable for laboratory determination of the combustion properties of plastic and non-metallic specimens in the horizontal or vertical direction under 50W flame conditions. [Meet the standard]: Design standard: GB-T2408-2008 “Testing of Combustion Properties of Plastics – Horizontal and Vertical Methods” (ANSI/UL94-2006) GBT10707-2008 “Determination of Rubber Combustion Performance” Method B (i.e., GB-T13488 “Determination of Rubber Combustion Performance – Vertical Combustion Method”) ANSI/UL94 GJB360B-2009 Test Methods for Electronic and Electrical Components GB/T5169.16-2008 IEC60950-1 【Product Features】: 1. Programmable controller touch screen + PLC control to realize the multi-function of control/detection/calculation/data display 2. High degree of automation: automatic recording of test time, automatic display of test results, automatic timing, automatic ignition, automatic return of the Bunsen lamp after the end of the flame, and you can choose whether to turn off the gas 3. You can choose whether to automatically ignite when starting 4. The front, back, up, down and back of the style clamp can be controlled by touch screen, start, stop, gas, timing, ignition, preservation, preservation, lighting, exhaust are all realized through touch screen control, and the test can be completed with a touch of fingertips 5. The timing button cooperates with PLC to automatically record the storage and burning time 6. The test time system automatically records and generates test results [Instrument parameters]: 1. Ambient temperature: room temperature ~40°C; Relative humidity: ≤75%; 2. Power supply voltage and power: 220V±10% 50HZ power 150W 3. The horizontal and vertical combustion test program can be switched on the touch screen, and the test results can be stored in the touch screen, and the test results can be queried; 4. Bunsen light automatic ignition, automatic timing, ignition time can be set arbitrarily (can be preset on the touch screen) 5. The inner diameter of the Bunsen lamp is 9.5mm±0.5mm 6. The Bunsen lamp can be selected whether to automatically ignite before starting 7. After applying the flame, the Bunsen lamp will automatically return, and the Bunsen lamp can be returned with the option of turning off the gas 8. Gas source: liquefied petroleum gas (methane gas for processing industry during arbitration); Note: The gas source and the link head user prepare their own steel plate electrostatic spray box 9. More than 0.5 cubic meters (support non-calibration to make 0.75m³, 1m³ size and stainless steel box) 10. Instrument weight approx.: 100kg 11. Working power supply: 220V AC 50HZ 12. Timing range: 0~999.9s Timing accuracy: 10s±0.2s 30s±0.2s; 13. Flame application time : 0~999.9S (adjustable, can be preset on touch screen) 14. Afterflame time: 0~999.9S 15. Afterburn time: 0~999.9S 16. Linear burning rate (V) PLC automatic calculation, touch screen display and save 17. Burning angle: 0°, 20°, 45° selectable 18. Flame height: 20mm ~ 130mm adjustable 19. Flame temperature: (100-1000)°C adjustable 20. Gas flow rate: 0ml/min-1000ml/min adjustable 21. The horizontal and vertical gas flow metering range is 12-120ml/min, the accuracy is level 4, the error is ±4.8ml/min, (optional 500) 22. Burning lamp: inner diameter of lamp 9.5±0.3mm, length: 100mm±10mm 23. Time device: accurate to 0.1S 24. Position adjustment: The sample clamp holder can be adjusted up and down, left and right, and the combustion seat can be adjusted back and forth, and the adjustment stroke is large 25. Flame Calibration Device: (Optional) 26. Temperature test range: 0~1000°C 27. Flame temperature requirements: from 100°C±5°C to 700°C±3°C within 44s±2s 28. Φ0.5mm (K-type) nickel-chromium/nickel-aluminum wire thermocouple, ground insulation 29. Heat transfer copper block: Ф5.5mm, mass 1.76g±0.01g 30. Gas alarm system (optional) 31. Dimensions: width 1160mm× depth 600mm× height 1310 mm (including feet). 32. Combustion test area volume: >0.5 cubic meters, length*width*height about 900mm×590mm×1050mm, background black, background illuminance ≤ 20Lux 33. The top is equipped with a silent and anti-backflow exhaust device, which can discharge the flue gas generated by combustion after the test

Related products