YG611B solar climate color fastness tester

YG611B solar climate color fastness tester

【Scope of application】
It is used for lightfastness, climate fastness and photoaging tests of non-ferrous materials such as textile, printing and dyeing, clothing, automobile interior parts, geotextile, leather, wood-based panel, wooden flooring, plastic, etc. By controlling the light irradiance, temperature, humidity, rain and other items in the test chamber, the simulated natural conditions required for the experiment are provided to test the light fastness, climate color fastness and photoaging properties of the samples. With online control of light intensity; Automatic monitoring and compensation of light energy; closed-loop control of temperature and humidity; Blackboard temperature loop control and other multi-point adjustment functions. Meets American, European and national standards. 【Relevant Standards】
    AATCC16,169、ISO105-B02、ISO105-B04、ISO105-B06、ISO4892-2-A、ISO4892-2-B、GB/T8427、GB/T8430、GB/T14576、GB/T16422.2、1865、1189、GB/T15102、GB/T15104、JIS 0843、GMW 3414、SAEJ1960、1885,JASOM346,PV1303, ASTM G155-1、155-4 and so on.
【Scope of application】: It is used for lightfastness, climate fastness and photoaging tests of non-ferrous materials such as textile, printing and dyeing, clothing, automobile interior parts, geotextile, leather, wood-based panel, wooden flooring, plastic, etc. By controlling the light irradiance, temperature, humidity, rain and other items in the test chamber, the simulated natural conditions required for the experiment are provided to test the light fastness, climate color fastness and photoaging properties of the samples. With online control of light intensity; Automatic monitoring and compensation of light energy; closed-loop control of temperature and humidity; Blackboard temperature loop control and other multi-point adjustment functions. Meets American, European and national standards. [Meet the standard]: AATCC16,169、ISO105-B02、ISO105-B04、ISO105-B06、ISO4892-2-A、ISO4892-2-B、GB/T8427、GB/T8430、GB/T14576、GB/T16422.2、1865、1189、GB/T15102、GB/T15104、JIS 0843、GMW 3414、SAEJ1960、1885,JASOM346,PV1303, ASTM G155-1、155-4 and so on. [Instrument features]: 1. Meet AATCC, ISO, GB/T, FZ/T, BS and many national standards. 2. Color touch screen display, multiple expressions: numbers, charts, etc.; It can display the real-time monitoring curve of light irradiance, temperature and humidity; And store a variety of detection standards, which is convenient for users to directly select and call. 3. Safety protection monitoring points (irradiance, water level, cooling air, temperature in the warehouse, warehouse door, overcurrent, overpressure) to realize the unmanned operation of the instrument. 4. Imported 3000W long arc xenon lighting system to truly simulate the sunlight spectrum. 5. The irradiance sensor position is fixed, which eliminates the measurement error caused by the rotation vibration of the turntable and the refraction of light from the specimen turntable to different positions. 6. Automatic compensation function of light energy. 7. Dynamic balance technology of temperature (irradiation temperature, heater heating), humidity (multi-set ultrasonic atomizer humidification, saturated water vapor humidification). 8. Precise and fast control of BST and BPT. 9. Water circulation and water purification device. 10. Independent timing function for each specimen. 11. Dual-loop electronic redundancy design ensures long-term continuous and trouble-free operation of the instrument. 【Technical Parameters】: 1. Display mode: color touch screen display; It can display real-time monitoring curves of light irradiance, temperature, and humidity 2. Long arc xenon lamp power supply: 220V, 50HZ, 3000W (max power) 3. Parameters of long arc xenon lamp: imported air-cooled xenon lamp, total length 460mm, electrode spacing: 320mm, diameter: 12mm. 4. Average service life of long arc xenon lamp: 1500 hours (including energy automatic compensation function, effectively extending the service life of the lamp) 5. Size of the solar instrument experimental chamber: 400mm×400mm×460mm(L×W×H) 4. Specimen rack rotation speed: 1~4rpm adjustable 5. Specimen clamp rotation diameter: 300mm 6. Number of specimen clips and effective exposure area of a single specimen clip: 16, 280mm×45mm(L×W) 7. Test chamber temperature control range and accuracy: room temperature ~48°C±2°C (under standard laboratory ambient humidity) 8. Humidity control range and accuracy of test chamber: 25%RH~85%RH±5%RH (under standard laboratory ambient humidity) 9. Blackboard temperature range and accuracy: BPT: 40°C~80°C±2°C Standard Blackboard Temperature Range and Accuracy: BST: 40°C~85°C±1°C (Digital Display, Automatic Monitoring, Closed-Loop Control) 10. Light irradiance control range and accuracy: Monitoring wavelength 300nm~400nm: (35~55) W/m2 ·nm± 1 W/m2 ·nm Monitoring wavelength 420nm: (0.550~1.300) W/m2 ·nm± 0.02 W/m2 ·nm Optional 340nm or 300nm~800nm and other bands for monitoring. Optical irradiance control mode: light irradiance sensor monitoring, digital setting, automatic compensation, stepless adjustment. 11. Instrument placement: floor placement 12. Overall Dimensions: 900mm×650mm×1800mm(L×W×H) 13. Power supply: 220V, 50HZ, 4500W 14. Weight: 230kg

Related products