【Scope of application】
It is used for the color and performance change test of various textiles, leather, artificial leather, plastics, fuels, coatings, paints and other non-ferrous materials, by adjusting the temperature and humidity of the experimental chamber, using xenon lamp and light filter system to reliably simulate the full spectrum of white light, and test the light and color fastness of the materials.
【Relevant Standards】
GB/T8427;GB/T8430;GB/T14576;GB/T15102;GB/T15104;AATCC TM16; ISO105-B02;ISO105-B04;ISO105-B06 and so on.
[Scope of application】:
It is used for the color and performance change test of various textiles, leather, artificial leather, plastics, fuels, coatings, paints and other non-ferrous materials, by adjusting the temperature and humidity of the experimental chamber, using xenon lamp and light filter system to reliably simulate the full spectrum of white light, and test the light and color fastness of the materials.
[Meet the standard.]】:
GB/T8427;GB/T8430;GB/T14576;GB/T15102;GB/T15104;AATCC TM16; ISO105-B02;ISO105-B04;ISO105-B06 and so on.
[Instrument characteristics】:
1. Adopt 3300W long-arc wind-cooled xenon lamp to truly simulate the daylight spectrum;
2. High transmittance filter combination, using 95% transmittance filter and filter cartridge, to achieve the same irradiance of light requirements with low power consumption, making the instrument more energy-saving and environmentally friendly;
3. Standard 420nm band, irradiance digital setting, real-time monitoring, closed-loop automatic adjustment, providing the most stable irradiance test light source for different standards (optional 340nm, 420nm, 300-400nm and 300-800nm bands);
4. Radiometer detection and wireless transmission use light energy conversion technology to provide energy, no need for a separate power supply;
5. Blackboard thermometer (BPT), standard blackboard thermometer (BST), irradimeter and sample are detected at the same station (equidistant) to truly reflect the tested condition of the sample, and the measured data is synchronously transmitted using wireless radio frequency technology.
6. Industrial refrigeration temperature control system, multi-stage ultrasonic humidification intelligent control system, quickly adjust the temperature and humidity in the test chamber to ensure accurate and stable test temperature and humidity;
7. A variety of operation modes (rain, light and dark, revolution), can simulate real climate conditions;
8. All specimen clips are timed separately, and different specimens can be tested on the same machine, which is convenient for testing and monitoring and reduces operating costs;
9. Adopt industrial color touch screen, a variety of test monitoring modes, easy to control, intuitive and clear;
10. The front and back of the specimen spray design, the specimen clamp can complete the rain climate test without 180° rotation;
11. Imported water filtration device, multi-point monitoring system, with automatic shutdown alarm protection function when the water level is too low and the air duct temperature is too high;
12. The safety protection of the whole power supply of the whole machine by German Müller electric appliances and the restart protection of the xenon lamp by the Japanese Omron power-off delay device comprehensively protect the stable operation of the instrument.
【Technical parameters】:
1. Xenon lamp source: 3300W air-cooled long-arc xenon lamp;
2. Test chamber temperature control range: 25~50°C; Resolution: 0.1°C;
3. Humidity control range of test chamber: optical cycle: 10~70RH%; Dark cycle: 30~95RH%; Resolution: 0.1RH%;
4. BST standard blackboard thermometer: 40~85°C; Accuracy: ±1°C; Resolution: 0.1°C;
5. BPT blackboard thermometer: 40~80°C; Accuracy: ±2°C; Resolution: 0.1°C; (optional)
6. Test time control range: ≤10000h;
7. Irradiance control mode: digital setting, real-time monitoring, closed-loop automatic compensation;
8. Irradiance monitoring wavelength: 420nm standard; 340nm, 300~400mm, 280~800nm optional;
9. Irradiance control range: 0.80~2.01W/m2@420nm; Accuracy: ±0.02W/m2@420nm;
10. Specimen rack rotation speed: 5rpm;
11. Number of specimen clips: 24 national standard; American Standard 18; (Double-layer specimen rack)
12. Each specimen clip is timed separately: ≤10000h;
13. Light period: ≤1000h;
14. Spraying cycle: ≤1000h;
15. Power source: AC220V±10%/50Hz;
16. Power: 6.5KW;
17. Overall dimensions: 920×650×1680mm;
18. Net weight: 180kg.